Narrated product demos, generated fully locally: speech synthesis, a scripted browser, ffmpeg. The first video had 12 seconds of voice over 8 seconds of picture. The one that passed every gate was 77 seconds of a frozen frame.
1 Nov 2026 · 2 min readThe portfolio needed demo videos for five apps. We built the pipeline locally, three stages:
1 narrate script → speech local text-to-speech (piper, English voice)
2 record Playwright screen recording, paced to stage 1's duration
3 merge ffmpeg, h264 + aac gate: |video − audio| ≤ 2.0 s
The decision that mattered
Synthesise first, measure the real audio length, then drive the browser for exactly that long. The reverse order, record then narrate, produced the first sample’s defect: 12 seconds of voice over 8 seconds of video.
The audio is the master clock. The scroll plan is scaled to fit it.
Three measurements
| what | measured | the trap |
|---|---|---|
| speech rate | 157–187 words per minute at script length | short test phrases gave 150 wpm: short utterances carry more lead-in silence and understate the rate |
| counting scroll steps | overshot 57.5 s by 4.34 s | ~1,300 browser round-trips, each slower than a frame; counted steps drift, a wall-clock deadline does not |
| pre-roll | 1.9–3.0 s | launching and loading the page is recorded video too; charge it to the scroll budget |
The drift fix: scroll inside the page with requestAnimationFrame against performance.now(), eased. Skew 4.34 s → 0.06 s.
The duration gate earned itself on run one: it failed on the real 4.34 s overshoot before any video shipped.
Results
| app | length | audio–video skew |
|---|---|---|
| Crystal RAG | 57.4 s | 0.06 s |
| The Wisdomkeeper | 59.4 s | 0.12 s |
| SEO Brain | 58.7 s | 0.59 s |
The defect the gate could not see
The fourth app’s dashboard is a fixed-viewport app. The page body is exactly as tall as the window, and window.scrollTo does nothing; the app scrolls an inner container, 1,880 px tall. The recorder measured the body, planned a scroll distance of 0, and produced 77 seconds of a motionless frame.
It passed the duration gate at 0.19 s skew. Perfectly in sync, completely useless.
The fixes:
- Find what actually scrolls: walk every element, pick the one with the most overflow, drive that. 0 → 1,291 px.
- A second gate on a different property: ffmpeg scene detection, at least three changes required.
- A negative control for it: a 20-second single-frame video scores 0; real takes score 179–586.
A gate that measures the wrong property passes the defect with full marks. Two gates on different properties, each with a negative control.
Two notes for anyone doing this with Playwright
- Pin the browser build to your Playwright version;
npx playwright installfetches the latest, which may not match. - The video file is written on
context.close(), not onpage.close().
The measurements in this article come from these records in the running system.
~/memory/2026-10-22-MEASURED-video-pipeline-the-clock-must-be-the-audio.md— video pipeline: the clock must be the audio
Demonstrating R2 CDN media delivery for alteranai: podcast audio (MP3, M4A), infographics (PNG), and slides (PDF)
Twelve modules we wrote by hand instead of installing a framework: rank fusion in 84 lines, a tool-call salvager in 197. What each replaced, and when a library is still the right call.
Gemma-4 26B swapped 27,848 times in a real agentic run. One flag reported zero, on an easy test. Under the load we actually run, it took two settings together: experts on the CPU and an 8-bit KV cache. No new runtime needed.